APPLICATIONS

2.2.8 Reference Pulse Inhibit Function (INHIBIT)

— 2-36 —

2.2.8 Reference Pulse Inhibit Function (INHIBIT)

The reference pulse inhibit function inhibits a Servopack for position control from counting
input reference pulses.

While this function is being used, the motor remains in Servo locked (clamped) status. The
/P-CON signal is used to enable or prohibit this function.

When this function is used, therefore, the /P-CON signal cannot be used to switch between
proportion (P) control and proportional/integral (PI) control for speed loop. (PI control is al-
ways used.)

Cn-01 bit F

Error

counter

Reference

pulse

0

1

OFF

ON

+

Feedback pulse

Servopack

/P-CON

/P-CON

Schematic Block Diagram for INHIBIT Function

Note

Use Cn-01 bit F to enable/disable the INHIBIT function.

Using Reference Pulse Inhibit Function (INHIBIT)

To use the INHIBIT function, set the memory switch Cn-01 bit F to 1:

Cn-01 Bit F

Reference Pulse Inhibit

Function (INHIBIT)

(1: Enable, 0: Disable)

Factory

Setting: 0

For Position Control

The INHIBIT function will be enabled.

Setting

Meaning

0

Does not use the INHIBIT function.

Reference pulses are always counted.
Uses the INHIBIT function.

/P-CON signal is used to enable or prohibit the INHIBIT function.

/P-CON

Meaning

1

OFF

Counts reference pulses.

1

ON

Prohibits the Servopack from counting reference

pulses.

The motor remains in Servo locked (clamped) status.

2

Positions

Positions