HEIDENHAIN TNC 360 ISO Programming User Manual
Page 203

TNC 360
1 1 - 4
11
Tables, Overviews, Diagrams
11.1 General User Parameters
Parameters for 3D touch probes
Signal transmission type
MP6010
Function
Value
• Cable transmission ........................................................................................................................................... 0
• Infrared transmission ....................................................................................................................................... 1
Traversing behavior of touch probe
Parameter
Function
Value
MP6120
Probing feed rate in mm/min ............................................................... 80 to 30 000
MP6130
Maximum measuring range to first scanning point in mm .................... 0 to 30 000
MP6140
Safety clearance over probing point
during automatic probing, in mm ........................................................... 0 to 30 000
MP6150
Rapid traverse for probe cycle in mm/min ........................................... 80 to 30 000
Parameters for TNC displays and the editor
Programming station
MP7210
Function
Value
• TNC with machine ........................................................................................................................................... 0
• TNC as programming station with active PLC ................................................................................................. 1
• TNC as programming station with inactive PLC .............................................................................................. 2