7.5 Checking and Changing Q Parameters
Q parameters can be checked during program run or during a test run, and
changed if necessary.
Preparation:
• A running program must be aborted (e.g. press machine STOP button
and STOP key).
• If you are doing a test run, you must interrupt it.
To call a Q parameter:
Q =
Select desired Q parameter (in this example Q10).
Q10 = + 100
The TNC displays the current value (in this example Q10 = 100).
Change Q parameter (in this example Q10 is changed to 0).
Leave the Q parameter unchanged.