beautypg.com

Output of q parameters and messages -11, 6 output of q parameters and messages – HEIDENHAIN TNC 360 ISO Programming User Manual

Page 145

background image

7-11

TNC 360

7

Programming with Q Parameters

Function D19: PLC transmits up to two numerical values or Q parameters
to the PLC.

Input increment and unit of measure: 1µm or 0.001°

Example: N25 D19 P01 +10 P02 +Q3 *

The number 10 corresponds to 10 µm or 0.01°

7.6 Output of Q Parameters and Messages

Displaying error messages

With the function D14: ERROR NUMBER you can call messages that
were pre-programmed by the machine tool builder.

If the TNC encounters a block with D14 during a program run or test run, it
interrupts the run and displays an error message. The program must then
be restarted.

Input example:

N50 D14 P01 254 *

The TNC will display the text of error number 254.

Error number to be entered

Prepared dialog text

0 to 299

ERROR 0 to ERROR 299

300 to 399

PLC ERROR 01 to PLC ERROR 99

400 to 483

DIALOG 1 to 83

484 to 499

USER PARAMETER 15 to 0

The machine tool builder may have programmed a text that differs from the above.

Output through an external data interface

The function D15: PRINT transmits the values of Q parameters and error
messages over the data interface. This enables you to send such data to
external devices, for example to a printer.

• D15: PRINT with numerical values up to 254

Example: N100 D15 P01 20 *
Transmits the corresponding error message (see overview for D14).

• D15: PRINT with Q parameter

Example: N200 D15 P01 Q20 *
Transmits the value of the corresponding Q parameter.

Up to six Q parameters and numerical values can be transmitted simulta-
neously.
Example: N250 D15 P01 4 P02 Q05 P03 4 P04 Q25 *

Assigning values for the PLC