beautypg.com

Creating a ticker, Creating a ticker -9 – Grass Valley Xpanel Vertigo Suite v.4.8 User Manual

Page 111

background image

Xpanel User Manual

6-9

Adding a data source to an object

Creating a ticker

Use a ticker when you want to scroll through a data set, displaying one or more items at
preset intervals. The item or items will be replaced with new content from a selected source.

To create a ticker:
1.

Open Xpanel’s Asset Browser (Ctrl+A) and select the D

ATA

tab.

2.

Right-click on the schema that you want to add the snapshot to and select the N

EW

T

ICKER

command.

The D

ATA

T

ICKER

S

ETTINGS

window appears.

3.

In the T

ICKER

N

AME

field enter a name for your ticker.

4.

Specify the T

ICKER

S

ETTINGS

:

a.

In the I

NTERVAL

(

SEC

) field, select the number of seconds you would like to elapse

before displaying the next data item.

b.

In the I

TEMS

field, select the number of data rows that are available for display.

c.

In the I

NCREMENT

field, select the number of rows you would like to increment. The

number of items must always be equal to or less than the increment number to
avoid data items being skipped.

d.

In the B

URST

field, select the number of data items you would like initially sent from

the D

ATA

S

ERVER

to the output device. If no burst is required, leave the count at 0.

N

OTE

The B

URST

setting is used with crawling or rolling tickers, and ensures that the first data item

will not repeat itself if subsequent data items are not sent to the device in time. If using the
B

URST

setting, it must be reset every time you go to P

RODUCTION

mode using two T

ICKER

C

OMMAND

actions (R

ESET

and S

TART

) associated with the panel’s O

N

L

OAD

event.

e.

Select the R

EFRESH

ONLY

AT

END

check box to refresh ticker data only after it has

gone through the entire table.

f.

Select the S

TART

B

Y

D

EFAULT

check box to have the ticker start running as soon

as its host control panel or page is activated. This is the only way to start it without
setting up an action.

g.

Select the W

RAP

AROUND

check box to have the ticker wrap. This feature is useful

if your ticker is showing, say, three data items at a time and you want to ensure
that if you reach the end of your table and there are only two items left, that you
don’t end up with a blank item. In this case, if W

RAP

AROUND

were selected the first

item from the table would go to air as the last item.

h.

Select the L

OOP

check box to have the ticker start at the beginning of the table and

play again after it has reached the end.

i.

Enable the I

NDIVIDUALISED

property when you want to allow each client to control

the state of the ticker independently.

This manual is related to the following products: