Installation

94

Planning and Installation Manual

mary Ref IN 1” connector on the rear panel. If additional references

are used, DIP switches are set to assign each board to one of four

possible sync lines. See

page 123

.

14.

If output monitoring is required, refer to the installation

instructions starting on

page 137

.

15.

On multi-chassis systems, the Frame number switches should be

checked. See

page 146

.

16.

Connect the switcher to the control system:

— For Jupiter control system connections and settings, see

page 148

.

— For SMS 7000 or Encore control system connections and

settings, see

page 153

.

17.

LAN and Com Bus connections and configuration of the Broadlinx

board (NR-33000 NIC/Sync/OPM board) are covered in the above

discussions about control systems.
The Broadlinx board is equipped with a plug-in, rechargeable

lithium-ion battery used to back up switcher status for Encore-con-

trolled systems. The battery is rated for approximately 500 power

cycles. If there is a power failure, and the battery fails to provide

power, the Broadlinx board will need to obtain router status from

the Encore System Control Module (data will be sent automati-

cally). For the location of this battery, see

page 119

.

18.

(Optional) Connect the rear panel ALARM BNC to the facility

alarm system. The alarm port operates according to SMPTE

standard 269M-1999.
For an overview of the alarm system, see

page 42

.

The rear panel Alarm BNC can be configured to report primary

alarms only or both primary and secondary alarms. The factory

default setting is to report both. DV-33128/33256 configuration is

via a jumper on the NR/SR-33000 board, as shown on

page 119

and

page 120

. DV-33512 configuration is via a jumper on the RP-33500

512 x 512 Rear Panel board as shown on

page 122

.

19.

Power up the system by connecting the AC power cords. If the LED

on the front panel turns to green after the first few seconds of

operation, the system is operating properly. If the LED continues to

glow red, remove power and diagnose the problem before

powering up the system again. For an explanation of LED alarm

lights, see

page 211

.

CAUTION For DV-33512 switchers: In order to avoid damage, power must be Off

before removing/installing the “IFC” cables.