6.

Refer to the Jupiter VM-3000 System Controller Installation and

Operation Manual, part no. 071 8305 xx or the Jupiter CM-4000

System Controller Installation and Operation Manual, part no. 071

8261 xx for control system installation details.

Note

Newer-model Trinix units have “1-based” input/output connector num-
bering; i.e., there is no connector “0.” However, Jupiter tables are always
0-based. When controlling such units, references to Physical Input/
Output connectors in Jupiter tables refer to that connector number plus
1. E.g., Physical Input 10 in the Jupiter Switcher Input table would cor-
respond to connector number 11 on the Trinix rear panel.