beautypg.com

Monitoring with expanded systems, Installation 144 planning and installation manual – Grass Valley Trinix v.2.4.1 User Manual

Page 144

background image

Installation

144

Planning and Installation Manual

Monitoring with Expanded Systems

In expanded systems, output monitor signals must be brought through

a combiner. An example of an output-expanded system in shown in

Figure 77

; and input-expanded system in shown in

Figure 78

.

Figure 77. Monitoring with Output-expanded System.

Figure 78. Monitoring with Input-expanded System.

Trinix

Frame 0

256 x 256

1 - 256

1 - 256

257 - 512

1 - 256

1 - 256

PE-33016s

used as

splitters

PE-33016

used as

combiner

Output monitor video

Output monitor video

QC station

Trinix

Frame 2

256 x 256

Trinix

Frame 0

256 x 256

1 - 256

1 - 256

257 - 512

257-512

1 - 256

PE-33016s

32

used as

combiners

PE-33016

used as

combiner

Dual outputs

Output monitor video

QC station

Trinix

Frame 1

256 x 256