Grass Valley Trinix v.2.4.1 User Manual
Page 183

System Configuration
Planning and Installation Manual
183
Auto-fill Editing Tool
When entering output numbers, a range of outputs can be assigned
with a single command. The range can be indicated with a “Start,Stop”
entry or a “Start+n” entry.
For example, at the Primary “12” row, in the “Secondary” field,
entering “258,260” would result in the following assignments:
Entering “258+2” would have the same result.
The auto-fill tool will not overwrite existing assignments.
Command Buttons
These buttons are located on the bottom of the protected paths menu.
Remove All Paths
This un-assigns all primary and secondary path links.
CAUTION Pressing the “Remove All Paths” button clears the table immediately.
There is no “Undo” for this command.
Add All Boards
The “Add All Boards” button will automatically assign the first half
of the router’s inputs as primary outputs and the second half as sec-
ondary outputs. In other words, the entire router would be config-
ured for protected path operation.
For example, using Add All Boards on a DV-33512 router would
assign output 1 as the primary path output with output 257 as the
associated secondary path output; output 2 as the primary path
output with output 258 as the associated secondary path output,
etc.
Back
Returns to the Signals page.
Enter
Applies output number(s) just entered.
Refresh
Checks router status and refreshes display.
Table 30.
Primary
Secondary
12
258
13
259
14
260