HI-33110 Input Card (SD/HD): automatic up to 100 meters
of Belden 1694A or equivalent coax cable.
VI-33100 Input Card (SD/HD): For digital SD operation,
automatic up to 300 meters of Belden 1694A or equivalent
coax cable. For HD operation, automatic up to 100 meters
of Belden 1694A or equivalent coax cable.
HI-33200 Input Card (SD/HD): For SD operation, auto-
matic up to 300 meters of Belden 1694A or equivalent coax
cable. For HD operation, automatic up to 100 meters of
Belden 1694A or equivalent coax cable.
Data reclocking:
Switch selectable on an output-by-output basis.
The HO-33110 Output Board provides individual selection
of reclocking for 1.485 Gbps or non-reclocking for all data
rates.
The HO-33120 Output Board provides individual selection
of reclocking On or Off for the supported data rates. The
data rate for reclocking is automatically selected by the cir-
cuitry on the board for 1.485 Gbps, 540 Mbps, 360 Mbps,
270 Mbps, 177 Mbps, and 143 Mbps. Other data rates will
not be reclocked.
The SO-33110 Output Board is non-reclocking.
Output jitter:
= 0.2 unit interval
AC Power Input
Mains connection:
IEC Connector, separate mains input for each power sup-
ply module
Voltage range:
100-240 VAC 50-60 Hz, universal, auto-ranging (fuses must
be selected and installed as appropriate for mains voltage)
Operating current
128 x 128 frame: approx. 5.36 A @ 100 VAC, approx. 2.23 A
@ 240 VAC.
256 x 256 frame: approx. 9.36 A @ 100 VAC, approx. 3.90 A
@ 240 VAC
512 x 512 frame: approx. 19.08 A @ 100 VAC; approx. 7.63 A
@ 240 VAC
Inrush current
128 x 128 frame: 49.05 A
256 x 256 frame: 55.0 A
512 x 512 frame: 45 A
Hold-up time:
Minimum 20 msec at full load
Conducted emissions: per FCC Class B, EN55022 Class B
Power Supply DC Output
Voltage:
+48 (+/-0.5) VDC
Current:
128 x 128 frame: 12.5 A/supply (full redundancy).