Grass Valley Trinix v.2.4.1 User Manual
Page 84

Planning Guide
84
Planning and Installation Manual
received, an extensive set of gain, phase, filtering, and other adjust-
ments are available for each signal. For a list of these adjustments,
see
• The HI-33201 SD/HD Digital Input mezzanine board auto-senses
and accepts a second set of 16 digital SD or digital HD signals in any
combination and passes them in digital SD or digital HD form (as
appropriate) to the Trinix matrix board.
TRX-HI-33200
SD/HD Digital Input Module - consists of a 16 input base board (HI-
33200) and a 16 input mezzanine board (HI-33201), providing a total of
32 inputs. Each board auto-senses and accepts 16 digital SD or digital
HD signals in any combination and passes them in digital SD or digital
HD form (as appropriate) to the Trinix matrix board. The TRX-HI-33200
is similar to the TRX-VI-33100 but is not fully stuffed.
TRX-SO-33110
SD Output Module, non-reclocked - consists of a 16 output base board
(SO-33110) and a 16 output mezzanine board (SO-33011), providing a
total of 32 outputs.
A “gain cell” is included on this board to be used in conjunction with
the port expanders in order to create multi-chassis routers as well as
dual or quad outputs. A switch is included to select one of four syn-
chronizing inputs.
TRX-HO-33110
HD Output Board, 1.5 G reclocked - consists of a 16 output base board
(HO-33110) and a 16 output mezzanine board (HO-33011), providing a
total of 32 outputs.
Each output can be set for Auto Detect “ON” or “OFF.” When Auto
Detect is ON the signal will be checked to see if it is a valid HD signal
running at 1.485 Gbps; if so, the signal will be reclocked; if not, it will
be bypassed. When Auto Detect is OFF the output signal is never
reclocked. A “gain cell” is included on this board to be used in conjunc-
tion with the port expanders in order to create multi-chassis routers as
well as dual or quad outputs. A switch is included to select one of four
synchronizing inputs.
TRX-HO-33120
Universal Output Module, multi-rate reclocker - consists of a 16-output
base board (HO-33120) and a 16-output mezzanine board (HO-33121).
Each output can be set for Auto Detect “ON” or “OFF.” When Auto
Detect is ON the signal will be checked to see if it is a valid HD or SD
signal running at a supported data rate; if so, the signal will be
reclocked; if not, it will be bypassed. When Auto Detect is OFF the
output signal is never reclocked. A “gain cell” is included on this board
to be used in conjunction with the port expanders in order to create