Installation

158

Planning and Installation Manual

Com Bus

In multi-frame systems, a “Com Bus” is used to loop through each

frame, up to a maximum of four. The Com Bus is intended to provide

switcher monitoring of multiple frames using Broadlinx web pages or

SNMP. The Com Bus uses a 10/100BaseT (Cat 5 twisted pair) cable with

RJ-45 connectors. Shielded cable is recommended, maximum length 60

meters.

1

Maximum length for unshielded cable is 100 meters.

Figure 91.

In DV-33512 systems, if the power supply chassis is equipped with an

NR-33000 Broadlinx board, install a Cat 5 twisted pair cable between

the power supply chassis Com Bus connector associated with the NR

board and one of the main chassis Com Bus connectors.

If there are additional DV-33512 main frames in the system, and

they do not have Broadlinx boards, then the Com Bus should be

daisy-chained to those frames also.

For an illustration, see

page 102

.

1.

Compliance with EEC, EMC, EN series, UL- 1950, and CSA C22.2 No. 950-M89 standards requires use of a shielded cable.

Com Bus cable
(see discussion
for specifications)

Trinix frames
with SR-33000
Sync/OPM
or SR-33500
Sync/OPM
boards

Trinix frame
with NR-33000
Sync/NIC/

OPM board
(Broadlinx
board)