beautypg.com

Jupiter control – Grass Valley Trinix v.2.4.1 User Manual

Page 148

background image

Installation

148

Planning and Installation Manual

Jupiter Control

Figure 80. Control connections to Jupiter Facility Control System (example).

The Jupiter Facility Control System can be used to control the Trinix

router using a VM-3000 System Controller (

Figure 80

). The VM can

receive switching commands from a variety of serial sources, including

Jupiter control panels or an automation computer. The new CM-4000

System Controller is also available as a control interface.

In this application, the Trinix is operated in the “external crosspoint bus

control” mode, during which the Broadlinx board releases control of

the crosspoint bus. Switch commands arriving at the crosspoint bus

connector on the rear of the chassis will be executed.

VM-3000

System

Controller

MPK bus

Trinix routing

switcher(s)

Crosspoint bus

Jupiter control panels

T

Crosspoint bus

terminator

Media

converter

or hub

Jupiter file

server

10/100BaseT

LAN

10Base2

LAN

T

T

T

Ungrounded

50-ohm terminator

=