Duplication and Expansion

Planning and Installation Manual

43

Duplication and Expansion

Trinix routers are designed to duplicate/expand inputs and outputs

using passive splitter/combiner expansion panels.

Note

For Jupiter-controlled (0-based) systems, the input/output numbers in
the following discussion should be decreased by one (1). For example,
block 1-256 should be understood as block 0-255, etc.

Note

Frame numbers are determined by the input/output blocks served by the
particular frame. E.g., for a DV-33256 router, inputs 1-256 and outputs
1-256 must be connected to frame zero. For more information about
frame numbering, see

page 146

.

Note

Unused connectors should be terminated for optimum performance.

Output Duplication - Dual

The PE-33016 Port Expander is a passive, transformer-based module

that can be used to provide two copies of the same signal. Functionality

is bi-directional and depends on connections only; no configuration is

needed.

Figure 13

and

Figure 14

show a splitting application. Note that

the unused connectors should be terminated for optimum perfor-

mance.

Figure 13.

Frame 0

Trinix

256 x 256

1 - 256

1 - 256

1 - 256

Dual outputs

16

PE 33016

used as

splitters