beautypg.com

Grass Valley Trinix v.2.4.1 User Manual

Page 45

background image

Duplication and Expansion

Planning and Installation Manual

45

Figure 15.

In this application, 16 of the PE-33016 rear BNCs can be used for inputs

(outputs from the router) and all 32 of the front BNCs can be used for

outputs.

1

Up to 16 PE-33016 modules can be mounted in the MK-33000 Mounting

Kit, which is eight rack units high and approximately four inches deep.

Figure 16

shows a 128 input router with a single PE-33016 mounted in

an MK-33000; this provides 112 single outputs and 16 dual outputs.

Figure 17

shows a 256 input router with 256 dual outputs; this arrange-

ment requires 16 PE-33016 Port Expanders.

1.

All unused connectors must be terminated. 16 terminators are supplied with each PE-33016. See

page 87

.

1 - 16

1 - 256

1 - 16

Dual outputs

1

PE 33016

used as

splitter

17 - 256

Single outputs

Frame 0

Trinix

256 x 256