Installation

114

Planning and Installation Manual

DV-33512 with Dual Sync References and Single/Dual NR-33000

Figure 53.

This arrangement is similar to that described on the previous page,

except that two sync references are used. The NR board in the Primary

slot will feed Sync Lines 1 and 2. If the NR is removed, Sync Lines 1 and

2 will automatically switch to the SR-33500.

Note

A secondary NR-33000 can installed to provide Broadlinx redundancy. In
this case, the NR REF IN 3 and 4 connectors would not be used.

For a discussion concerning which of the two sync references should be

connected to the control system, see

Sync Connection to Control System

on page 109

.

Jupiter

Sync 1

2

1 Primary NR-33000

Secondary NR-33000

1

2

3

4

SR-33500

Output
board(s)
on SL1

Output
board(s)
on SL2

Sync Lines

Sync 2

SMS MCPU

Sync 1

or

Encore SCB

OR

Sync Redundant switch = Off

“C” switch = Off

See

Note

Sync

1

T

T

Some DV-33512 power supply units

are not labelled correctly. See drawing

on

page 102

for correct REF IN con-

nector labelling.