Planning Guide

76

Planning and Installation Manual

Com Bus

In multi-frame systems, a “Com Bus” is used to loop through each

frame, up to a maximum of four. The Com Bus is intended to provide

switcher monitoring of multiple frames using Broadlinx web pages or

SNMP. The Com Bus uses a 10/100BaseT (Cat 5 twisted pair) cable with

RJ-45 connectors. Shielded cable is recommended, maximum length 60

meters.

1

Maximum length for unshielded cable is 100 meters.

Figure 38.

In DV-33512 systems, if the power supply chassis is equipped with an

NR-33000 Broadlinx board, a Cat 5 twisted pair cable must be installed

between the power supply chassis Com Bus connector associated with

the NR board and one of the main chassis Com Bus connectors.

If there are additional DV-33512 main frames in the system, and they do

not have Broadlinx boards, then the Com Bus should be daisy-chained

to those frames also.

For an illustration, see

page 102

.

1.

Compliance with EEC, EMC, EN series, UL- 1950, and CSA C22.2 No. 950-M89 standards requires use of a shielded cable.

Com Bus cable
(see discussion
for specifications)

Trinix frames
with SR-33000
Sync/OPM
or SR-33500
Sync/OPM
boards

Trinix frame
with NR-33000
Sync/NIC/

OPM board
(Broadlinx
board)