background image

Rear Panel Dip Switch Settings

Planning and Installation Manual

103

Rear Panel Dip Switch Settings

Input/Output Expand

See

page 124

.

Sync Redundant

Note

This switch may be labelled “VIT Redundant” on some units.

If the system is equipped with a secondary NR-33000 board, closing

this switch will provide continued operation in case of a single NR

failure. However, operating in the redundant mode will limit the

number of possible sync sources to two. In DV-33512 systems, if Sync

Redundant mode is selected the “C” switch must also be closed. For

more information, see

page 111

and

page 115

.

Internal Xpt (Crosspoint) Control

Open = Trinix crosspoint bus is controlled by an external crosspoint bus

controller (e.g., a Jupiter VM-3000 or CM-4000; or, an NR board in

another frame).

Closed = Trinix crosspoint bus is controlled by an internal crosspoint

controller (i.e., an NR-33000 Sync/NIC/OPM board). This setting is

used when the NR is in turn being controlled through a LAN connec-

tion to a control system such as a Grass Valley Series 7000 Signal Man-

agement System or Encore.

For more information, see

page 148

and

page 153

60 Hz Enable Switch

This switch is reserved for future use.

A B C Switches

The “A” switch is reserved for future use.
The “B” switch is closed in output-monitor-expanded systems where

output monitor signals are brought through a combiner. See

page 144

.

The “C” switch must be closed in DV-33512 systems whenever the Sync

Redundant switch is closed. This will prevent use of any sync reference

connected to the SR-33500 Sync/OPM board.

INPUT EXPAND

OUTPUT EXPAND

SYNC REDUNDANT
INT XPT CNTL

60Hz ENABLE

A
B
C

OPEN

CLOSED