Termination for pre-wired expansion frames, Input expansion – Grass Valley Trinix v.2.4.1 User Manual

Page 56

background image

Planning Guide

56

Planning and Installation Manual

Termination for Pre-wired Expansion Frames

As described above, unused BNC connectors on port expanders should

be terminated for best performance. However, it may be desirable to

install an empty or partially stuffed frame and associated cabling to

simplify future expansion, and when such cabling connects to a port

expander that is carrying active signals, special termination hardware

is required. Since the presence of pre-wired cabling will not permit

standard BNC terminators to be installed on the expander, an LD-33100

Loader board is installed in the associated frame in place of an input or

output board to provide correct termination.

Figure 25. LD-33100 Loader board

Input Expansion

For example,

Figure 26

shows a 512 x 512 system expandable to 1024 x

512:

Figure 26.

Frame 1 contains no input or output boards, but wiring has already

been installed between Frame 1 and the PE-331016 Port Expanders.

Frame 0

Trinix

512 x 512

1 - 512

1 - 512

Future input
wiring

1 - 512

outputs

32

PE 33016

used as

combiners

Trinix

512 x 512

Frame 1

(unused)

Installed pre-wiring

Output slots should be terminated
using LD-33100 Loader boards