Time Management

Broadlinx time settings are used only to timestamp the “Events” log

entries. The menu is shown in

Figure 102

.

Figure 102.

This clock will synchronize automatically to a VITC signal on line 14

1

of the sync reference input.

The Daylight Savings Time box must be checked or unchecked manu-

ally at the appropriate time during the year.

The UTC Offset is the number of hours that standard time at the cus-

tomer location is ahead or behind Universal Time Coordinated (Green-

wich Mean Time). For example, for the U.S. Eastern time zone the entry

would always be “-5:00.”

If a SNTP (Simple Network Time Protocol) server will be used as a time

source, select the SNTP radio button and enter the IP address of the

server.

The SNTP address can also be changed on the Configure Net Interface

menu. If the SNTP server is on another network you may need to enter

the IP address of the gateway to that network (see

page 175

).

If no external reference is available, the clock will run in stand-alone

mode. In this case, click the “Manual” button and enter the appropriate

values.

System Description

This is the source of the system name that appears on the left side of the

top-level Broadlinx page (

Figure 95 on page 167

).

1.

per SMPTE RP 164-1996.