Config worksheet – Grass Valley iControlEdge v.1.20 Installation User Manual
Page 79

Config Worksheet
75
2. If desired, change the ALARM NAME—this will change the text displayed in the monitoring
application.
3. If you wish to discontinue monitoring for a specific alarm, insert two asterisk in the first column of the
corresponding row, or delete the entire row. The alarm will be removed from all Alarm Panels and will
no longer be calculated or displayed.
Config Worksheet
To define the alarm behavior and other options for your iControl Edge configuration:
•
Click the Config tab, and specify the appropriate values for the attributes described in the table below.
The Config worksheet defines alarm behavior, and other options:
ALARM TYPE
The type of alarms (“TEXT”, “STATUS”, or “COMPRESSED”).
LEVEL
Specifies whether the alarm belongs to the Device or Service category. An alarm
set to the “SERVICE” level is visible in the service’s alarm panel, and its state
contributes to the overall alarm status for this service. The service’s button color
in the Channel Selector area represents this overall alarm status. An alarm set to
the “DEVICE” level is also visible in the service’s alarm panel, but its state does not
contribute to the alarm status for this service (and thus does not affect the color
of the corresponding Channel Selector button).
Note: Do not edit the ALARM URI.
Column
Description
Alarm status indicators
Compressed alarm status indicators