231
2.
Configure PE 2:
# Configure GigabitEthernet 1/0/1 as a trunk port, and assign the port to VLAN 100.
[PE2] interface gigabitethernet 1/0/1
[PE2-GigabitEthernet1/0/1] port link-type trunk
[PE2-GigabitEthernet1/0/1] port trunk permit vlan 100
[PE2-GigabitEthernet1/0/1] quit
# Configure GigabitEthernet 1/0/2 as a trunk port, and assign the port to VLAN 100.
[PE2] interface gigabitethernet 1/0/2
[PE2-GigabitEthernet1/0/2] port link-type trunk
[PE2-GigabitEthernet1/0/2] port trunk permit vlan 100
[PE2-GigabitEthernet1/0/2] quit
3.
Configure PE 3:
# Configure GigabitEthernet 1/0/1 as a trunk port, and assign the port to VLANs 100 and 200.
[PE3] interface gigabitethernet 1/0/1
[PE3-GigabitEthernet1/0/1] port link-type trunk
[PE3-GigabitEthernet1/0/1] port trunk permit vlan 100 200
# Configure a two-to-two VLAN mapping on GigabitEthernet 1/0/1 to map SVLAN 100 and
CVLAN 5 to SVLAN 200 and CVLAN 6.
[PE3-GigabitEthernet1/0/1] vlan mapping tunnel 100 5 translated-vlan 200 6
[PE3-GigabitEthernet1/0/1] quit
# Configure GigabitEthernet 1/0/2 as a trunk port, and assign the port to VLAN 200.
[PE3] interface gigabitethernet 1/0/2
[PE3-GigabitEthernet1/0/2] port link-type trunk
[PE3-GigabitEthernet1/0/2] port trunk permit vlan 200
[PE3-GigabitEthernet1/0/2] quit
4.
Configure PE 4:
# Configure the network-side port GigabitEthernet 1/0/1 as a trunk port, and assign the port to
VLAN 200.
[PE4] interface gigabitethernet 1/0/1
[PE4-GigabitEthernet1/0/1] port link-type trunk
[PE4-GigabitEthernet1/0/1] port trunk permit vlan 200
[PE4-GigabitEthernet1/0/1] quit
# Configure the customer-side port GigabitEthernet 1/0/2 as a hybrid port. Assign the port to
VLAN 6 and VLAN 200 as a tagged member and an untagged member, respectively.
[PE4] interface gigabitethernet 1/0/2
[PE4-GigabitEthernet1/0/2] port link-type hybrid
[PE4-GigabitEthernet1/0/2] port hybrid vlan 6 tagged
[PE4-GigabitEthernet1/0/2] port hybrid vlan 200 untagged
# Configure a one-to-two VLAN mapping on the customer-side port GigabitEthernet 1/0/2 to add
SVLAN tag 200 to traffic from VLAN 6.
[PE4-GigabitEthernet1/0/2] vlan mapping nest single 6 nested-vlan 200
[PE4-GigabitEthernet1/0/2] quit
- H3C S5130 Series Switches H3C S5120 Series Switches H3C SR8800 H3C SR6600-X H3C SR6600 H3C MSR 5600 H3C MSR 50 H3C MSR 3600 H3C MSR 30 H3C MSR 2600 H3C MSR 20-2X[40] H3C MSR 20-1X H3C MSR 930 H3C MSR 900 H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module