189

Step

Command

Remarks

4.

Configure the Join timer.

mrp timer join timer-value

Optional.
The default setting is 20

centiseconds.

5.

Configure the Leave timer.

mrp timer leave timer-value

Optional.
The default setting is 60

centiseconds.

6.

Configure the Periodic timer.

mrp timer periodic timer-value

Optional.
The default setting is 100

centiseconds.
You can restore the Periodic timer

to the default at any time.

Table 16

shows the value ranges for Join, Leave, and LeaveAll timers and their dependencies.

If you set a timer to a value beyond the allowed value range, your configuration fails. You can set
a timer by tuning the value of any other timer. The value of each timer must be an integer multiple

of 20 centiseconds and in the range defined in

Table 16

.

When you restore the default settings for the timers, H3C recommends that you restore the timers in
the order of Join, Leave, and LeaveAll.

Table 16 Dependencies of the Join, Leave, and LeaveAll timers

Timer Lower limit

Upper limit

Join

20 centiseconds

Half the Leave timer

Leave

Twice the Join timer

LeaveAll timer

LeaveAll

Leave timer on each port

32760 centiseconds

Enabling GVRP compatibility

Enable GVRP compatibility for MVRP when the peer device supports GVRP. Then, the local end can

receive and send both MVRP and GVRP frames.
When you enable GVRP compatibility, follow these restrictions and guidelines:

GVRP compatibility enables MVRP to work with STP or RSTP, but not MSTP.

When the system is busy, disable the Period timer to prevent the participant from frequently
registering or deregistering attributes.

To enable GVRP compatibility:

Step Command

Remarks

1.

Enter system view.

system-view N/A

2.

Enable GVRP

compatibility.

mvrp gvrp-compliance
enable

By default, GVRP compatibility is disabled.