The trunk promiscuous port GigabitEthernet 1/0/1 is a tagged member of primary VLAN 5 and
secondary VLANs 2 and 3.
•
The host port GigabitEthernet 1/0/2 is an untagged member of primary VLAN 5 and secondary
VLAN 2.
•
The host port GigabitEthernet 1/0/3 is an untagged member of primary VLAN 5 and secondary
VLAN 3.
Trunk promiscuous and trunk secondary port configuration
example
Network requirements
As shown in
, configure the private VLAN feature to meet the following requirements:
•
VLANs 10 and 20 are primary VLANs on Device A. The uplink port GigabitEthernet 1/0/5 on
Device A permits the packets from VLANs 10 and 20 to pass through tagged.
•
VLAN 11, VLAN 12, VLAN 21, and VLAN 22 are secondary VLANs on Device A.
{
The downlink port GigabitEthernet 1/0/2 permits the packets from VLAN 11 and VLAN 21 to
pass through tagged.
{
The downlink port GigabitEthernet 1/0/1 permits VLAN 22.
{
The downlink port GigabitEthernet 1/0/3 permits VLAN 12.
•
Secondary VLANs 11 and 12 are associated with primary VLAN 10.
•
Secondary VLANs 21 and 22 are associated with primary VLAN 20.
Figure 49 Network diagram
Configuration procedure
1.
Configure Device A:
- H3C S5130 Series Switches H3C S5120 Series Switches H3C SR8800 H3C SR6600-X H3C SR6600 H3C MSR 5600 H3C MSR 50 H3C MSR 3600 H3C MSR 30 H3C MSR 2600 H3C MSR 20-2X[40] H3C MSR 20-1X H3C MSR 930 H3C MSR 900 H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module