Configuring common ethernet interface settings, Configuration prerequisites, Changing the active port of a combo interface – H3C Technologies H3C S5560 Series Switches User Manual
Page 16
2
Configuring common Ethernet interface settings
This section describes the settings common to Layer 2 and Layer 3 Ethernet interfaces. You can set an
Ethernet interface as a Layer 3 interface by using the port link-mode route command. For more
information, see "
Configuring the link mode of an Ethernet interface
." For more information about the
settings specific to Layer 2 and Layer 3 Ethernet interfaces, see "
Configuring a Layer 2 Ethernet interface
"
Configuring a Layer 3 Ethernet interface
Configuring a combo interface (only applicable to
S5560-30F-EI switches)
A combo interface is a logical interface that physically contains one fiber combo port and one copper
combo port. The two ports share one forwarding channel and one interface view. As a result, they cannot
work simultaneously. When you activate one port, the other port is automatically disabled. In the
interface view, you can activate the fiber or copper combo port, and configure other port attributes such
as the interface rate and duplex mode.
For more information about the number of combo interfaces, see the installation guide.
Configuration prerequisites
Use the display interface command to determine which port (fiber or copper) of each combo interface is
active:
•
If the copper port is active, the output includes "Media type is twisted pair."
•
If the fiber port is active, the output does not include this information.
Also, you can use the display this command in the view of each combo interface to display the combo
interface configuration:
•
If the fiber port is active, the combo enable fiber command exists in the output.
•
If the copper port is active, the combo enable fiber command does not exist in the output.
Changing the active port of a combo interface
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enter Ethernet interface
view.
interface interface-type interface-number
N/A
3.
Activate the copper
combo port or fiber
combo port.
combo enable { copper | fiber }
By default, the copper combo
port is active.
- H3C S5130 Series Switches H3C S5120 Series Switches H3C SR8800 H3C SR6600-X H3C SR6600 H3C MSR 5600 H3C MSR 50 H3C MSR 3600 H3C MSR 30 H3C MSR 2600 H3C MSR 20-2X[40] H3C MSR 20-1X H3C MSR 930 H3C MSR 900 H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C WX3000 Series Unified Switches H3C LSWM1WCM10 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module