background image

16

CHAPTER 1 • USING THE CLICK 500

The right-side of this figure details the connections made to wire to a DCE DB-9 female

connector and then link to a computer via a straight-through serial cable. The TD and RD

labels on the serial cable are not referenced to the DCE device (Click 500) but rather to the

DTE device (PC). The arrows show the direction of flow; transmit data on the DTE device

becomes received data on the DCE device and vice-versa. This reversal of roles is why you

connect pin 2 of the DCE DB-9 female connector to the TD screw terminal and pin 3 to the

RD screw terminal.

NC

NC

TD

RD

RS-232 Top Connector

DCE

DB9 Female

DTE

DB9 Male

(Computer)

1

2

3

4

5

GND

1

2

3

4

5

Serial Cable

RD

TD

To GND on

RS-485 Connector

2

3

Figure 1.4 – RS 232 Top

RS-485 Ports

The RS-485 serial ports are located on the T-bus connector, the RS-485 terminal block on

top of the module and the RJ-11 connector located on the front of the module. The RS-485

terminal on the top of the module and the RJ-11 jack on the front are electrically connected

and represent a single serial port. Figure 1.5 below shows the RS-485 pin-level descriptions

for this port. The other RS-485 serial port on the T-bus connector is physically independent

(see Figure 1.2).

-485

+485

GND

GND

RS-485 Top Connector

RS-485 Front (RJ-11)

Connector

1

2 3

4

5

6

The RS-485 lines are shared

between these two connectors

GND

-485

+485

NC

Figure 1.5 – RS-485 Top/Front Connector