beautypg.com

Product specifications, Accuracy datashuttle-16 accuracy & resolution, Datashuttle- 16 thermocouple accuracy – Measurement Computing DataShuttle User Manual

Page 31

background image

DataShuttle and DynaRes

11-13-01

DataShuttle - Technical Notes 2-13

Product Specifications

Accuracy DataShuttle-16 Accuracy & Resolution-

Range

Typical Resolution

at Full Scale

Absolute Accuracy, the larger of

% of Range: % of Reading:

-5 to +50 mV

.8µV

0.04%

-

-25 to +25 mV

.8µV

0.08%

-

-50 to +500 mV

8µV

0.01%

0.05%

-250 to +250 mV

8µV

0.01%

0.05%

-1 to +10 mV

150µV

0.01%

0.05%

V

O

LTA

GE

-5 to +5 mV

150µV

0.01%

0.10%

General Conditions – From 15 to 35 degrees C, ambient at the interface unit, source resistance less than
1k Ohms. Includes linearity, drift, offset, resolution, and calibration error.

If you are using a DataShuttle-5B, be sure to add the uncertainty of the isolation modules being used
to these specifications.

DataShuttle- 16 Thermocouple Accuracy

Type

Range (°C.)

Resolution (°C.)

Accuracy (°C.)

J

-210 to –100

0.1 – 0.3

± 2.3

-100 to 0

0.05

± 1.2

0 to 880

0.05 – 0.2

± 1

K

-250 to –75

0.15 – 1.0

± 8

-75 to 1260

0.07 – 0.3

± 1.4

0 to 900

0.06 – 0.2

± 1.2

E

-250 to –70

0.1 – 0.5

± 4

-70 to 100

0.04

± 1

100 to 680

0.04 – 0.15

± 0.8

T

-250 to –50

0.15 – 0.8

± 6

-50 to 10

0.02 – 0.8

± 1.4

10 to 150

0.06

± 1.2

150 to 400

0.06 – 0.1

± 1

S

-50 to 120

0.4

± 10

120 to 380

0.3

± 5

380 to 1770

0.2 – 0.6

± 4

R

-50 to 250

0.2 – 0.4

± 10

250 to 800

0.2

± 4

800 to 1770

0.2 – 0.4

± 3

B

200 to 300

0.7 – 1

± 20

300 to 500

0.4 – 0.7

± 13

500 to 1000

0.2 – 0.4

± 8

1000 to 1820

0.2 – 0.4

± 4

G

25 to 200

0.2 – 1

± 15

200 to 2315

0.15 – 0.8

± 4

D

-20 to 2315

0.2 – 1

± 4

150 to 2000

0.15 – 0.6

± 3

C

-20 to 2315

0.15 – 1

± 4

100 to 1500

0.15 – 0.4

± 3

N

-200 to –100

0.7 – 1.4

± 5

-100 to 1300

0.4 – 0.7

± 3

This manual is related to the following products: