Wiring

TopKAT PLUS Installation Procedures

Wiring

Types of Wiring

The wiring in the terminal block differs in accordance with the type of pump controlled by the
TopKAT PLUS. There are several types of pumps:

• Mechanical pumps
• Electronic pumps

Following section provides the

“Wiring Requirements”

for each type of pump:

Wiring Requirements

Before inserting any wire to the terminal block, proceed as follows:

1

Insert the wire with a terminal lug only (see

Figure 3-9

).

2

Attach the lug to the wire using the proper terminal crimper.

3

For UL-listing, the terminal lug must be a UL recognized component.

Figure 3-9: Terminal Lug

Note: Mark each cable at its both ends with a number or sign that will identify its functionality

in the future.

Types of Cables

Following cables are required for the TopKAT PLUS installation:

• Power cable: In accordance with local regulations
• LAN cable: CAT-5E [refer to

“Field Wiring Requirements (LAN/WAN)”

on

page 3-12

]

• RS-485/pulser: Communication cable, twisted-pair, separately shielded, low capacitance.

For example, Belden 8723 or equivalent.

Note: The shield must be connected to ground on one side of the cable only, preferably on the

TopKAT PLUS side.