beautypg.com

Electrical setup, Electrical setup -11 – Gasboy TopKAT PLUS User Manual

Page 17

background image

MDE-5013C TopKAT™ PLUS Installation Manual · February 2015

Page 1-11

Electrical Setup

Introduction

Electrical Setup

TopKAT PLUS electrical components are protected by a dedicated cover to ensure physical
separation between high voltage and low voltage in the box. The mains cable is first connected
to the terminal block. Between the terminal block and transformer, the system uses a line filter
to attenuate conducted radio frequencies - Radio Frequency Interference (RFI),
Electromagnetic Interference (EMI) - between the line and equipment. AC power is then
supplied to an AC/AC high to low transformer - 110/220 to 25 VAC.

Figure 1-11

shows the AC setup in electronic pumps configuration without the protective

cover.

Figure 1-11: AC Setup (Electronic Configuration)

32 V Regulator

(M09680B052)

Line Filter (M09680B008)

24 V Regulator

(M09680B083)

Transformer

(M09680B022)

Terminal Block (M09680B025)