Appendix F: Rawtrans File Layout
Page F-2
MDE-4589 PC TopKAT™ Online Operation and Setup Manual · August 2010
01 = timed out
02 = locked out
03 = invalid fuel
04 = pump in use
06 = limit cutoff
09 = normal completed transaction
10 = fallback completed transaction
13 = odometer range error
14 = invalid PIN
17 = pump disabled
19 = invalid pump
23 = emergency stop
31 = power fail
34 = invalid tank
35 = dipstick transaction W/ water entry
37 = dipstick transaction W/O water entry
38 = dipstick transaction W/ water entry conversion error, tank not
found
39 = dipstick transaction W/O water entry conversion error, tank
not found
40 = dipstick transaction W/ water entry conversion error, tank not
found
41 = dipstick transaction W/O water entry conversion error, tank
not found
42 = fallback dipstick transaction W/O water entry
43 = fallback dipstick transaction W/ water entry
44 = fallback invalid driver entry
45 = invalid driver entry
51 = pump switch timer error
55 = delivery transaction
56 = fallback delivery transaction
60 = memory loss transaction
61 = unassigned transaction
62 = dual pulser error
63 = no record found
64 = daily limit exceeded
65 = pump out of service
67 = supervisor transaction
Rental
Agreement
8
Numeric
Zero filled
Sample Records
Notes
1234121234200208221100123412345678912121212345678901123456781234561212345678
1001010001200208221352000100000000201010100000010000000000000050000900000001
Normal Fueling
Transaction
1001010002200208221353000200000000300010100005000000001000000000003500000000
Dipstick
Transaction
1001010003200208221354000200000000400010100003000000000000000000005500000000
Delivery
Transaction
Field Name
Size
Type
Notes