beautypg.com

Fuel point reader, Input and output redirection, Cpu board – Gasboy CFN III Quick Reference Guide v3.3 User Manual

Page 62

background image

CFN III Quick Reference

Page 58

MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005

connect to a Site Controller. Use this option only if
you connect to the Site Controller through a dial-out
modem and you want to override the number in the
password file. P requests pulse (rotary) dialing, T
requests touch dialing, and a comma requests the
modem to pause 2 seconds in the dialing sequence to
wait for a second dial tone.
Another phone number option is the modem timeout
length. That is the time the modem will wait for an
answer. The modem timeout length is the number of
seconds surrounded with square brackets [], typed
after the /D.
/L Output usually appears on the screen. This
option will make the output also print on the PC
printer.
/Ttimeout Specify how long to wait for a response
from the Site Controller. The time is specified in
eighteenths of a second (18 = 1 second); default and
shortest timeout allowed is 3 (0.167 seconds).
siteid Specify the site ID number. Use this option
only for sites you are dialing up with a modem, not
for direct-connect sites. Use an asterisk (*) as the site
ID to call all the sites in the password file.

Input and Output

Redirection

If you use site-control mode, the input and output
files will be on the PC’s disk, instead of the Site
Controller’s disk. Similarly, printed output will be
printed on the PC’s printer, instead of the Site
Controller’s printer.
<filename uses the commands from the named file as
input.
>filename puts the output of the commands in the
named file, deleting whatever was in the named file.
>>filename adds the output of the commands to the
end of the named file.
>PRN prints the output of the commands on the PC
printer (site-control mode).
>LOG prints the output of the commands on the site
printer (terminal mode).

Fuel Point

Reader

CPU Board

Part number: C08886.
4-wire operation:
RS 485 PCB to RS-485 JBOX

1 - Tx+ (CFN422-1)
2 - Tx- (CFN422-2)
4 - Rx- (CFN422-4)
3 - Rx+ (CFN422-3)

Switches

DIP Switch Bank 1
DIP switch 1 on the fuel point reader terminal CPU
board sets options, including the reader terminal
address:

Switch Setting

1

always on

2

always on

3

address - see below

4

address - see below

FPR address

Switch 3

Switch 4

1

OFF

OFF

2

OFF

ON

3

ON

OFF

4

ON

ON

Switch Setting

DL1

Receive from vehicle module

DL2

Transmit to vehicle module

DL3

Receive from fuel management system

DL4

Transmit to fuel management system

This manual is related to the following products: