Rs-232 communications, Modems and cables – Gasboy CFN III Quick Reference Guide v3.3 User Manual
Page 59

CFN III Quick Reference
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
Page 55
Jumper Setting
Setting
Default
K1K2
position 1=slave
side of 422/485
loop transmits
position
2=master side of
422/485 loop
transmits
position 1
K3K4
position 1=tank
monitor or PC or
Profit Point
position 2=other
application if
position 1 doesn’t
work
position 1
K5
always on
on
K6
on=232 device
listens to slave
responses, or for
PC monitor
off=tank gauge
off=Profit Point
off
K7
on=232 device
listens to master
side of 422/485
loop
on
R1 - Adjusting
R1 should be adjusted only if you are using a PC
monitor and the data being displayed is scrambled.
1. Turn R1 20 full turns counterclockwise.
2. Slowly turn R1 clockwise until the data display
clears up.
3. Start counting turns.
4. Continue turning R1 clockwise until the data
starts to scramble again.
5. Turn R1 counterclockwise half the number of
turns you counted in order to position it in the
middle of the acceptable range.
RS-232
Communications
Modems and Cables
PC Package/Answer modem
Kit number: C01533
Parameter settings
Set SYS_PAR, page 8, Remote CFN Port Type:
3 = direct connect or dumb modem, full duplex.
Setup procedure:
1. Connect a terminal to the modem with a 1:1
cable male DB-25 to male DB-25 (C04549) or
male DB-25 to female DB-9 (C04654).
2. Connect the modem’s power cord and turn
modem power switch ON.
3. Use the steps below:
Hayes/Hayes-Compatible 14.4 and above
Type: AT&F&D2S0=1&C1B1&Q6X0&K0&W
↵
Modem responds: OK
Type: ATQ1&W
↵
Modem does not respond
Note: If a Panasonic data terminal (or other data
terminal requiring DCD) is being used to configure
the modem, set the parameter in the terminal to
Ignore the DCD level of the RS-232 signal. This is
necessary because the AT&C1&W command causes
the modem to drop DCD which may be required by
the terminal being used to configure the modem
unless the terminal is set up to ignore the DCD level.
Bank Network modem
Kit number: C05899
For SCII, CFN3, or Islander II with a network
interface that requires the fuel management system to
contact a bank network for verification of a user’s
card.
System:
Set remote port modem type to Hayes with
handshake.
Modem:
For bank networks, call for current modem part
number.
For Networks with a menu selection:
Set the modem type to the approved purchased type
of modem. See the appropriate Credit and Debit Card
Network manual for specific modem information.
For Networks without a menu selection:
Set SYS_PAR, page 8, Host Handler Data:
01 = Hayes 2400.