CFN III Quick Reference

MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005

Page 55

Jumper Setting

Setting

Default

K1K2

position 1=slave

side of 422/485
loop transmits

position

2=master side of
422/485 loop
transmits

position 1

K3K4

position 1=tank

monitor or PC or
Profit Point

position 2=other

application if
position 1 doesn’t
work

position 1

K5

always on

on

K6

on=232 device
listens to slave

responses, or for
PC monitor

off=tank gauge
off=Profit Point

off

K7

on=232 device
listens to master

side of 422/485
loop

on

R1 - Adjusting

R1 should be adjusted only if you are using a PC
monitor and the data being displayed is scrambled.
1. Turn R1 20 full turns counterclockwise.
2. Slowly turn R1 clockwise until the data display

clears up.

3. Start counting turns.
4. Continue turning R1 clockwise until the data

starts to scramble again.

5. Turn R1 counterclockwise half the number of

turns you counted in order to position it in the
middle of the acceptable range.

RS-232

Communications

Modems and Cables

PC Package/Answer modem

Kit number: C01533

Parameter settings

Set SYS_PAR, page 8, Remote CFN Port Type:
3 = direct connect or dumb modem, full duplex.

Setup procedure:
1. Connect a terminal to the modem with a 1:1

cable male DB-25 to male DB-25 (C04549) or
male DB-25 to female DB-9 (C04654).

2. Connect the modem’s power cord and turn

modem power switch ON.

3. Use the steps below:

Hayes/Hayes-Compatible 14.4 and above
Type: AT&F&D2S0=1&C1B1&Q6X0&K0&W

Modem responds: OK

Type: ATQ1&W

Modem does not respond

Note: If a Panasonic data terminal (or other data
terminal requiring DCD) is being used to configure
the modem, set the parameter in the terminal to
Ignore the DCD level of the RS-232 signal. This is

necessary because the AT&C1&W command causes
the modem to drop DCD which may be required by
the terminal being used to configure the modem
unless the terminal is set up to ignore the DCD level.

Bank Network modem

Kit number: C05899
For SCII, CFN3, or Islander II with a network
interface that requires the fuel management system to
contact a bank network for verification of a user’s
card.

System:

Set remote port modem type to Hayes with
handshake.

Modem:

For bank networks, call for current modem part
number.
For Networks with a menu selection:

Set the modem type to the approved purchased type
of modem. See the appropriate Credit and Debit Card
Network manual for specific modem information.
For Networks without a menu selection:

Set SYS_PAR, page 8, Host Handler Data:
01 = Hayes 2400.