Rs-232 communications, Modems and cables – Gasboy CFN III Quick Reference Guide v3.3 User Manual
Page 59

CFN III Quick Reference
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
Page 55
Jumper Setting
Setting
Default
K1K2
position 1=slave
side of 422/485 
loop transmits 
position
2=master side of 
422/485 loop 
transmits 
position 1
K3K4
position 1=tank
monitor or PC or 
Profit Point 
position 2=other
application if 
position 1 doesn’t 
work 
position 1
K5
always on
on
K6
on=232 device 
listens to slave 
responses, or for 
PC monitor 
off=tank gauge 
off=Profit Point 
off
K7
on=232 device 
listens to master 
side of 422/485 
loop 
on
R1 - Adjusting
R1 should be adjusted only if you are using a PC 
monitor and the data being displayed is scrambled. 
1. Turn R1 20 full turns counterclockwise. 
2. Slowly turn R1 clockwise until the data display 
clears up.
3. Start counting turns. 
4. Continue turning R1 clockwise until the data 
starts to scramble again.
5. Turn R1 counterclockwise half the number of
turns you counted in order to position it in the 
middle of the acceptable range. 
RS-232
Communications
Modems and Cables
PC Package/Answer modem
Kit number: C01533
Parameter settings
Set SYS_PAR, page 8, Remote CFN Port Type: 
3 = direct connect or dumb modem, full duplex. 
Setup procedure: 
1. Connect a terminal to the modem with a 1:1 
cable male DB-25 to male DB-25 (C04549) or 
male DB-25 to female DB-9 (C04654). 
2. Connect the modem’s power cord and turn
modem power switch ON.
3. Use the steps below:
Hayes/Hayes-Compatible 14.4 and above  
Type: AT&F&D2S0=1&C1B1&Q6X0&K0&W 
↵
Modem responds: OK
Type: ATQ1&W
↵
Modem does not respond
Note: If a Panasonic data terminal (or other data 
terminal requiring DCD) is being used to configure 
the modem, set the parameter in the terminal to 
Ignore the DCD level of the RS-232 signal. This is 
necessary because the AT&C1&W command causes 
the modem to drop DCD which may be required by 
the terminal being used to configure the modem 
unless the terminal is set up to ignore the DCD level. 
Bank Network modem
Kit number: C05899 
For SCII, CFN3, or Islander II with a network 
interface that requires the fuel management system to 
contact a bank network for verification of a user’s 
card. 
System:
Set remote port modem type to Hayes with 
handshake. 
Modem:
For bank networks, call for current modem part 
number. 
For Networks with a menu selection: 
Set the modem type to the approved purchased type 
of modem. See the appropriate Credit and Debit Card 
Network manual for specific modem information. 
For Networks without a menu selection: 
Set SYS_PAR, page 8, Host Handler Data: 
01 = Hayes 2400. 
