CFN III Quick Reference

Page 2

MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005

invalid.

Option: C

CHKDSK disk-based command to check the R
drive integrity.

Options: [-A] [-B ###] [-F] [-R]
-A read and check entire disk
-B if the disk error message shows bad sectors,
use this option with the sector numbers to mark
those sectors
-F attempt to fix disk if lost or cross-linked
clusters or length errors are found
-R read all files to check for bad sectors

CLOSE (154) makes a retroactive safe drop to the
previous shift; used only in command files, never by
itself on a command line.
compare a shift-change command to compare two
character strings without case sensitivity.

Options: [string1] [string2]

CONSOLE disk-based configuration program for
console.

Options: [-P][-V] [filename]
-P print current configuration
-V display in TTY form if port is configured as
a CRT in the system parameters, or vice versa

CP (105) command to copy disk files quickly.

Options: A I
file1 file2 | file1 [file2] dir

COPy (105) copies a disk file.

Options: A I
file1 file2

DEactivate PUmp (14) shuts off a pump from the
terminal.

Options: C A
A option takes a pump out of full serve mode

DELete (6) removes a disk file or files on the R
drive only.

Option: A
A option deletes any specified file, even read-
only and hidden files

DIRectory (4) prints a listing of disk file names.

Options: I A
I option gives listing in short format
A option lists hidden files

DIsable COnsole (19) shuts down a console.

Option: C

DIsable DUmp (106) turns off file dumping.
DIsable FPR (162) shuts down a fuel point reader.

Option: C

DIsable GAte (88) shuts down a gate controller.

Option: C

DIsable HIstory (107) turns off system history
recording.
DIsable PCu (20) shuts down a pump control unit.

Option: C

DIsable PROduct (108) disables product attributes.

Option: C
0 prompt displays ?Price?, not ?Amount?
1 product is not a refund
2 product is not a payout
3 product is not a withdrawal
4 disables dollar amount inventory for product
5 disables inventory tracking for product
7 low inventory not indicated by asterisk in
PRINT PRODUCT
8 product is not a fuel product
9 journal does not use category number as
department number
15 disable patronage (Buypass only)

DIsable PUmp (21) shuts down a pump.

Options: C A
A option disables all pumps

DIsable RAW (109) turns off raw mode.
DIsable REader (22) shuts down a card reader
terminal.

Option: C

DIsable SDI (163) shuts down SDI.

Option: C

DIsable TMS (86) shuts down a tank monitor
system (gauge).

Option: C

DOwnload SDI (100) forces a download of an SDI.
Include the SDI number(s) on the same line as the
command, no C option is needed.

This manual is related to the following products: