Gasboy CFN III Quick Reference Guide v3.3 User Manual
Page 6
CFN III Quick Reference
Page 2
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
invalid.
Option: C
CHKDSK disk-based command to check the R
drive integrity.
Options: [-A] [-B ###] [-F] [-R]
-A read and check entire disk
-B if the disk error message shows bad sectors,
use this option with the sector numbers to mark
those sectors
-F attempt to fix disk if lost or cross-linked
clusters or length errors are found
-R read all files to check for bad sectors
CLOSE (154) makes a retroactive safe drop to the
previous shift; used only in command files, never by
itself on a command line.
compare a shift-change command to compare two
character strings without case sensitivity.
Options: [string1] [string2]
CONSOLE disk-based configuration program for
console.
Options: [-P][-V] [filename]
-P print current configuration
-V display in TTY form if port is configured as
a CRT in the system parameters, or vice versa
CP (105) command to copy disk files quickly.
Options: A I
file1 file2 | file1 [file2] dir
COPy (105) copies a disk file.
Options: A I
file1 file2
DEactivate PUmp (14) shuts off a pump from the
terminal.
Options: C A
A option takes a pump out of full serve mode
DELete (6) removes a disk file or files on the R
drive only.
Option: A
A option deletes any specified file, even read-
only and hidden files
DIRectory (4) prints a listing of disk file names.
Options: I A
I option gives listing in short format
A option lists hidden files
DIsable COnsole (19) shuts down a console.
Option: C
DIsable DUmp (106) turns off file dumping.
DIsable FPR (162) shuts down a fuel point reader.
Option: C
DIsable GAte (88) shuts down a gate controller.
Option: C
DIsable HIstory (107) turns off system history
recording.
DIsable PCu (20) shuts down a pump control unit.
Option: C
DIsable PROduct (108) disables product attributes.
Option: C
0 prompt displays ?Price?, not ?Amount?
1 product is not a refund
2 product is not a payout
3 product is not a withdrawal
4 disables dollar amount inventory for product
5 disables inventory tracking for product
7 low inventory not indicated by asterisk in
PRINT PRODUCT
8 product is not a fuel product
9 journal does not use category number as
department number
15 disable patronage (Buypass only)
DIsable PUmp (21) shuts down a pump.
Options: C A
A option disables all pumps
DIsable RAW (109) turns off raw mode.
DIsable REader (22) shuts down a card reader
terminal.
Option: C
DIsable SDI (163) shuts down SDI.
Option: C
DIsable TMS (86) shuts down a tank monitor
system (gauge).
Option: C
DOwnload SDI (100) forces a download of an SDI.
Include the SDI number(s) on the same line as the