Rs-232 character framing, Print transaction, Site-host mode – Gasboy CFN III Quick Reference Guide v3.3 User Manual
Page 60

CFN III Quick Reference
Page 56
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
CFN3 to Modem
For CFN3 to modem use part number C05995.
CFN3 to Okidata
For CFN3 to Okidata use part number C05994.
RS-232 Character
Framing
ASCII, 8 data bits, no parity, 1 stop bit.
Print Transaction
Host-Site Mode
Code = PT; options = A
The Site Controller response is:
ppttttyymmddhhnneennnnnnvvvvvvvv
aa...aa,[00..00]tdwkii...iikeeeepppp
Completed Transaction Codes
Code
Message*
Meaning
7
Refund
transaction is a refund**
8
Return
transaction is a return**
9
Payout
transaction is a payout**
10
Mem Lost
pump control unit’s memory was
lost due to battery failure
40
Pwr Fail
transaction terminated due to a
power failure at the pump
control unit
41
normal transaction
42
Timed Out
transaction timed out at the
pump
43
Limit
pump cut off at limit
45
Reversal
transaction is a reversal
50
Unassigned
a device completed a transaction
but the Site Controller does not
have a record of it.
52
Gate
transaction was started at a gate
controller
54
Aborted
transaction was aborted (p ump
was deactivated) before
pumping was completed
55
Delivery
transaction is a fuel delivery,
either manually entered at the
card reader terminal*** or
registered by a tank monitor
71
Manual
transaction was manually
entered at the card reader
terminal***
77
Pulse err
caused by dual pulser failure
78
Prod out
pump reports it is out of this
type of product
79
Pump down a pump is not working**
81
Withdrawal transaction was a cash
withdrawal**
* The message printed in the Error field of the
transaction printout.
** Site Controller II and III.
*** Site Controller I only
Site-Host Mode
Standard log in—an example of the sign-on
command and response with calculated CRC-16
check sums:
0 2V010,