The following is a list of ports and their assignments:

Name

Chnl

Location

Function

CON

0

PC CRT/Keyboard

Local port login

SC1

1

COMM CPU right DIN

RS232

SC2

2

COMM CPU 26 pin

ribbon

RS232 all cont.

lines

SC3

3

COMM MEM DB-9*

Tokheim pumps

SC4

4

COMM MEM bottom DIN*

RS232

SC5

5

COMM MEM middle DIN*

RS232 jumperable

SC6

6

COMM MEM right DIN*

RS232 jumperable

COM1

7

P C

RS232

COM2

8

P C

RS232

COM3

9

P C

RS232

COM4

10

P C

RS232

LPT1

11

P C

Parallel output

LPT2

12

P C

Parallel output

LOOP1

N/A

COMM CPU bottom handset* Island loop

LOOP2

N/A

COMM CPU middle handset* Island loop

LOOP3

N/A

COMM CPU right handset*

POS loop

* refer to diagram on previous page

Internal Profit Point

setup

Plug the power supply into the Gasboy distribution
box next to the word power. Plug the other end into
an outlet.
Plug cables into their correct positions. Com2 of the
computer connects into serial2 of the Gasboy
distribution box.
Com3 on the computer connects to serial3 of the
Gasboy distribution box.

Diagnostic

Error Codes


The following error codes may appear in response to
PRINT DIAGNOSTICS;A.

Console

Errors in console-to-Site Controller messages:
CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
PIN—PIN errors
RDE—card read error

Errors in Site Controller-to-console messages:
NB3—buffer busy
NB5—invalid command
NB7—receiver overrun
NBA—bad cyclical redundancy check (CRC)

Card & Gate Reader

Errors in reader-to-Site Controller messages:
CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response
PIN—PIN errors
RDE—read error

Errors in Site Controller-to-reader messages:
NB3—buffer in use
NB4—not hexadecimal
NB5—invalid command
NB6—undefined EE command number
NB7—overflow/framing error
NB8—input buffer overrun
NB9—alphanumeric display busy
NBA—bad cyclical redundancy check (CRC)

Pump Control Unit

Errors in PCU-to-Site Controller messages:
CRC—bad cyclical redundancy check (CRC)
DIE—device went down
NOR—no response

This manual is related to the following products: