Vacuum fluorescent display – Gasboy CFN III Quick Reference Guide v3.3 User Manual
Page 35

CFN III Quick Reference
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
Page 31
Option Menus
Selections
console address
1 2 3 4
keyswitch type
4 position
2 position
cash drawer
yes no
drawer switch type
dr clo=sw closed
dr clo=sw open
beeper
enabled disabled
alert beep type
short long no no
alert beep repetition*
15 sec 8 sec
4 sec 2 sec
key click type
short medium long none
LED color
normal reversed
dead man timer
on off
console printer/pad**
none present
printer address
01 01-64
DES
disabled enabled
receipt line feed, top
0 1-10
receipt line feed, end
10 00-18
receipt left margin
04 00-10
printer
Star undefined
printer port
serial parallel
decimal position
.00 none .0 .000
decimal point
period comma
ignore scan
57 36-59, 62-77, 99
ignore scan
99 36-59, 62-77, 99
ignore scan
99 36-59, 62-77, 99
ignore scan
99 36-59, 62-77, 99
ignore scan
99 36-59, 62-77, 99
* in version 5.3e
** for Star RS-422 printer, set to none
While an option in each group is displayed, pressing:
• ENTER selects the currently displayed option
and causes an option in the next group to display.
• 1 selects the next option in that group.
• 2 defaults to the first option in that group.
• 0 exits configuration mode and saves your
changes.
• PREV selects the currently displayed option and
displays the previous group.
• 7 returns you to the initial configuration display.
RS-422/485 Loopback Connector
Pin connections: 1 to 3 (black to green) and 2 to 4
(red to yellow).
Vacuum Fluorescent
Display
DIP switch bank 1 on the Check Point fluorescent
display board sets options:
VF Display on
Switch 1 Definition
Console
Cust. Display
1
----
open
open
2
----
open
open
3
TEST**
open
open
4
MASTER
closed
open
5
SLAVE
open
closed
6
----
open
open
7
----
open
open
8
----
open
open
**in version 3.0; position 6 activates the self test in
version 3.1.
Notes
1-3, TEST—If closed, the display performs a rotating
barber-pole-pattern self test. The last four characters
in the pattern have all dots lit.
1-4, MASTER—If closed, display transmits
characters via its serial interface as it displays them.
This switch should be closed on the display in the
Check Point if a remote display is used also.
1-5, SLAVE—If closed, display listens on its serial
interface and displays all characters received there.
This switch should be closed if a display is being
used as a remote display connected to the display in
the Check Point.