beautypg.com

Vacuum fluorescent display – Gasboy CFN III Quick Reference Guide v3.3 User Manual

Page 35

background image

CFN III Quick Reference

MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005

Page 31

Option Menus

Selections

console address

1 2 3 4

keyswitch type

4 position

2 position

cash drawer

yes no

drawer switch type

dr clo=sw closed
dr clo=sw open

beeper

enabled disabled

alert beep type

short long no no

alert beep repetition*

15 sec 8 sec

4 sec 2 sec

key click type

short medium long none

LED color

normal reversed

dead man timer

on off

console printer/pad**

none present

printer address

01 01-64

DES

disabled enabled

receipt line feed, top

0 1-10

receipt line feed, end

10 00-18

receipt left margin

04 00-10

printer

Star undefined

printer port

serial parallel

decimal position

.00 none .0 .000

decimal point

period comma

ignore scan

57 36-59, 62-77, 99

ignore scan

99 36-59, 62-77, 99

ignore scan

99 36-59, 62-77, 99

ignore scan

99 36-59, 62-77, 99

ignore scan

99 36-59, 62-77, 99

* in version 5.3e
** for Star RS-422 printer, set to none

While an option in each group is displayed, pressing:
• ENTER selects the currently displayed option

and causes an option in the next group to display.

• 1 selects the next option in that group.
• 2 defaults to the first option in that group.
• 0 exits configuration mode and saves your

changes.

• PREV selects the currently displayed option and

displays the previous group.

• 7 returns you to the initial configuration display.

RS-422/485 Loopback Connector
Pin connections: 1 to 3 (black to green) and 2 to 4
(red to yellow).

Vacuum Fluorescent

Display

DIP switch bank 1 on the Check Point fluorescent
display board sets options:

VF Display on

Switch 1 Definition

Console

Cust. Display

1

----

open

open

2

----

open

open

3

TEST**

open

open

4

MASTER

closed

open

5

SLAVE

open

closed

6

----

open

open

7

----

open

open

8

----

open

open

**in version 3.0; position 6 activates the self test in
version 3.1.

Notes
1-3, TEST—If closed, the display performs a rotating
barber-pole-pattern self test. The last four characters
in the pattern have all dots lit.
1-4, MASTER—If closed, display transmits
characters via its serial interface as it displays them.
This switch should be closed on the display in the
Check Point if a remote display is used also.
1-5, SLAVE—If closed, display listens on its serial
interface and displays all characters received there.
This switch should be closed if a display is being
used as a remote display connected to the display in
the Check Point.