Electronic pump interfaces, Tokheim – Gasboy CFN III Quick Reference Guide v3.3 User Manual
Page 53

CFN III Quick Reference
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
Page 49
Electronic
Pump
Interfaces
Tokheim
Single Channel To Tokheim 67 Box or 98 Box
For single channel use Tokheim cable, C07081.
98 Box
TALK DISP should be connected to +9V with a
1K Ohm resistor. DC COM should be connected to
GND.
Dual Channel To Tokheim 67 Box or 98 Box
Dual Channel to Tokheim 67 or 98 box, use cable
C05996 that has the following layout.
CFN3 Pump Configuration
In the PUMP configuration program, in submenu 1,
set Maximum Units to Gallons and Maximum
Amount to 999 Gallons.
In the PUMP configuration program, in submenu 3,
set the following options:
Tokheim type
Options to set
162/262
2,7
262-A
2,7,8,9,13
SA MMD
1,2,7,8,9
SA MMD $/Cr
1,2,3,7,8,9
TCS
1,2,7,8,9,13
TCS $/Cr
1,2,3,7,8,9,13
TCS 1 hose blend
1,2,7,8,9,12,13,19
TCS 1 hose blend $/Cr
1,2,3,7,8,9,12,13,19
TCS 1 hose, multigrade, non-blend 1,2,7,8,9,13,19
TCS 1 hose, multigrade non blend $/Cr
1,2,3,7,8,9,13,19
Premier
1,2,7,8,9,13,16
Premier $/Cr
1,2,3,7,8,9,13,16
Premier 1 hose blend
1,2,7,8,9,13,16,19
Premier 1 hose blend $/Cr
1,2,3,7,8,9,13,16,19
Premier blender
1,2,7,8,9,13,16
Premier blender $/Cr
1,2,3,7,8,9,13,16
Premier 1 hose, 1 prod
2,7,8,9,13,16
Premier 1 hose, 1 prod $/Cr
1,2,3,7,8,9,13,16
Premier 1 hose, multigrade
1,2,7,8,9,13,16,19
Premier 1 hose, multigrade $/Cr
1,2,3,7,8,9,13,16,19
The options in the above table are:
1 Pump is a multi-product dispenser.
2 Pump always needs switch detect (off-hook) to
activate.
3 Pump has a cash-credit select button. (Customer
can choose cash or credit payment at the pump.)
4 Site Controller can activate the pump without
knowing the price or hose (for some MPDs).
5 Site Controller cannot choose the hose number
or price (for some MPDs).
6 Site Controller cannot get the dollar amount or
volume during pumping.
7 Pump can’t do switch detect or pulser timeouts
(timeouts must be done by the driver).
8 Pump is a Tokheim stand-alone dispenser or
Gasboy SPD v4.3+/PAC v4.2+.
9 Pump can only be activated from downloaded
prices (the displayed prices are downloaded).
10 Pump never needs switch detect to activate (can
be activated while it is still on-hook).
11 The PCU is slow to respond to requests
(improves performance on pumps that are
Site Contr
oller
Male DB-9
Connector
Tokheim
16-pin Amp cir
cular
connectors
1 TTDA
2
3 TTCA
TTDB 4
5
TTDA 2
6 DCCA
TTCB 5
10
TTCA 3
1 TTDB
DCCB 6
2
DCCA 7
3 TTCB
5
6 DCCB
10