Raw mode error codes, Profit point, Tank monitor – Gasboy CFN III Quick Reference Guide v3.3 User Manual
Page 27: Back panel, Scanner

CFN III Quick Reference
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
Page 23
Errors in Site Controller-to-PCU messages:
NB0—invalid hose number or price level
NB1—pump in use
NB2—transaction data unavailable
NB4—not hexadecimal
NB5—invalid command
NB6—invalid pump number
NB7—overrun
NB8—buffer overflow
NB9—test
NBA—bad cyclical redundancy check (CRC)
NBD—power failure
NBE—RAM contains transaction data
Tank Monitor
CRC—bad cyclical redundancy check (CRC)
DIE—number of communication losses
NOR—no response
Raw Mode
Error Codes
The following error codes may appear in conjunction
with the %E error variable.
Code Meaning
Code Meaning
00
Completed, Ok,
Passed
15
Valid card, bit
mapped
01
Transaction(s) in
progress
16
Valid card, limited
02
Not found or does
not exist
17
Invalid card, bit
mapped
03
Invalid data
18
Invalid card,
limited
04
Card is valid
19
Expecting NC,
NW, or NY
05
Card is not valid
20
String too long
06
Device out of
service
21
Print heading
before record
07
Pump is in use
22
Some valid, some
not
08
Pump is not on
23
Already exists
09
Illegal command
24
Invalid price
10
Command failed
25
Can’t open file
11
No more file space
26
Site not stopped
12
Manager key
required
27
Can’t activate
13
Site is stopped
28
Gate in use
14
Invalid option
Profit Point
Back panel
The back panel of the non-modular Profit Point looks
like this:
The back panel of the modular Profit Point looks like
this:
Scanner
The scanner should be set to the following
parameters when the scanner is attached to the
scanner port:
2400 baud (non-modular)
1200 (modular)
7 bits (non-modular)
8 bits (modular)
parity even (non-modular)
no parity (modular)
2 stop bits (non-modular)
1 stop bit (modular)
RS-232 prefixes disabled
CTS/RTS disabled
RS-232 output carriage return only