Raw mode error codes, Profit point, Tank monitor – Gasboy CFN III Quick Reference Guide v3.3 User Manual
Page 27: Back panel, Scanner

CFN III Quick Reference
MDE-4483 CFN III Quick Reference Guide v3.3 · August 2005
Page 23
Errors in Site Controller-to-PCU messages: 
NB0—invalid hose number or price level 
NB1—pump in use 
NB2—transaction data unavailable 
NB4—not hexadecimal 
NB5—invalid command 
NB6—invalid pump number 
NB7—overrun 
NB8—buffer overflow 
NB9—test 
NBA—bad cyclical redundancy check (CRC) 
NBD—power failure 
NBE—RAM contains transaction data 
 
Tank Monitor
CRC—bad cyclical redundancy check (CRC) 
DIE—number of communication losses 
NOR—no response 
 
Raw Mode
Error Codes
The following error codes may appear in conjunction 
with the %E error variable.
Code Meaning
Code Meaning
00
Completed, Ok, 
Passed 
15
Valid card, bit 
mapped 
01
Transaction(s) in 
progress 
16
Valid card, limited
02
Not found or does
not exist
17
Invalid card, bit
mapped
03
Invalid data
18
Invalid card, 
limited 
04
Card is valid
19
Expecting NC, 
NW, or NY 
05
Card is not valid
20
String too long
06
Device out of 
service 
21
Print heading 
before record 
07
Pump is in use
22
Some valid, some 
not 
08
Pump is not on
23
Already exists
09
Illegal command
24
Invalid price
10
Command failed
25
Can’t open file
11
No more file space
26
Site not stopped
12
Manager key 
required 
27
Can’t activate
13
Site is stopped
28
Gate in use
14
Invalid option
Profit Point
Back panel
The back panel of the non-modular Profit Point looks 
like this: 
 
The back panel of the modular Profit Point looks like 
this: 
Scanner
The scanner should be set to the following 
parameters when the scanner is attached to the 
scanner port: 
 
2400 baud (non-modular)
1200 (modular)
7 bits (non-modular)
8 bits (modular)
parity even (non-modular)
no parity (modular)
2 stop bits (non-modular)
1 stop bit (modular)
RS-232 prefixes disabled 
CTS/RTS disabled 
RS-232 output carriage return only 
 
