Comtech EF Data MDX420 SkyWire Manual User Manual
Page 79
MDX420 SkyWire™ Satellite Network Gateway
SkyWire Controller (GUI)
MN-MDX420 Revision 6
7–23
Figure 7.4.6-2
Major
Alarms:
o
Mod FPGA
Indicates a transmit FPGA configuration failure.
o
Encoder FPGA Indicates a transmit encoder configuration failure.
o
LO Synthesizer Indicates that the Tx L-Band Synthesizer is not locked. This alarm
will flash on during certain gateway parameter changes. A solid indication points
toward a configuration problem within the gateway.
o
Share Group Config The burst modulator and that active listener burst demodulator
satellite configuration parameters do not match
Minor
Alarms:
o
Output Level
Indicates that the Output Level is out of specification.
o
BUC Voltage
Indicates that the BUC voltage is out of specification
o
BUC Current
Indicates that the BUC Current is out of specification.
o
Mesh Authorization Indicates the Gateway/Authorization ID number cannot be detected
on the mesh network.
o
Carrier Level Cal The gateway has not been properly calibrated
o
DC Offset Cal The gateway has not been properly calibrated