beautypg.com

Comtech EF Data MDX420 SkyWire Manual User Manual

Page 74

background image

MDX420 SkyWire™ Satellite Network Gateway

SkyWire Controller (GUI)

MN-MDX420 Revision 6

7–18

properly join the share group. NOTE: If entered incorrectly the remote site will not join the
network.

Circuit Name – Text name to help identify the circuit. The circuit name is not a required field but if
entered, the circuit name will appear as a tooltip when the mouse hovers over a remote’s
graphics bar on the Demodulator Summary Status screen.

Assigning a SkyWire gateway to the network as Remote 1 is a simple three step process (Figures
7.4.3-1 through 7.4.3-3).

1

Click on the Create control button on the left of the first position in the Remotes table.

2

Click on the Edit control button to begin entering the network parameters:

set the appropriate CIR, DIR, MIR
antenna elevation angle,
enter the Access Code,
circuit name (if desired)
check the Enable button

3

Click Apply to enter the new settings.

Repeat the process for all SkyWire Gateways that need to join this network. This process is also
used when a new gateway is being added to an existing share group.

Figure 7.4.3-1

Figure 7.4.3-2

Figure 7.4.3-3

Figure 7.4.3-4

To temporarily remove a remote from the network after it has been created, encheck the
“Enabled” box. To permanently remove a remote from the network after it has been created, click
the “Destroy” button. Clicking the Destroy button (Figure 7.4.3-4) disables the gateway assigned
to that position, clears the position in the table and permanently removes all user entered data for
that site. NOTE: Disabling or destroying a site you are locally connected to will terminate any
access to other sites in the network from this device.

Network Configuration Notes:

1

The Step Size value is based on the symbol rate, modulation and coding of the shared carrier.

2

The settings for DIR and CIR must be equal to or multiples of the Step Size.

3

Also when configuring the settings of DIR, CIR and MIR, the relationship must be as follows:
DIR <= CIR <= MIR.

4

The sum of all CIRs in the share group must be less than the Data Rate shown in the Channel
section of the screen.