Terminal Screens
MN-MDX420 Revision 6
6–9
6.2.4.5 Demodulator
Alarms
(Common to all installed Burst Demodulators)
DEMODULATOR ALARM STATUS 1 THROUGH 4
DEMOD FPGA
{Pass/Fail, Unmasked/Masked}
Indicates a receive FPGA hardware failure.
DECODER FPGA
{Pass/Fail, Unmasked/Masked}
Indicates a decoder failure.
TUNER PLL
{Pass/Fail, Unmasked/Masked}
Indicates that the Rx L-Band Synthesizer is not locked. This alarm will flash on
during certain gateway parameter changes. A solid indication points toward a
configuration problem within the gateway.
SIGNAL LOCK
{Pass/Fail, Unmasked/Masked}
Indicates that the burst demodulator is unable to lock to a signal.
IFEC LOCK
{Pass/Fail, Unmasked/Masked}
FRAME LOCK
{Pass/Fail, Unmasked/Masked}
Indicates that the Framing Unit is unable to find the expected framing pattern.
ESNO Fault
{Pass/Fail, Unmasked/Masked}
Indicates Rx signal quality fallen below input threshold.
CARRIER LEVEL
{Pass/Fail, Unmasked/Masked}
Indicates Rx signal level has fallen below input threshold.
TESTPRN SYNC
{Pass/Fail, Unmasked/Masked}
Indicates Rx pattern is synchronized to the data pattern
CLEAR LATCHED
Allows the user to reset the latched alarms by selecting