7–22
7.4.6 Configure Alarms
Demod Alarms: To view the detailed alarms of the burst demodulator(s), select the tab for the
Demod 1-4. The Detailed Alarms screen for the selected burst demodulator (Figure 7.4.6-1) will
be displayed.
Figure 7.4.6-1 Detailed Alarams
Major
Alarms:
o
Demod FPGA Indicates a receive FPGA hardware failure.
o
Decoder FPGA Indicates a decoder failure.
o
Tuner PLL
Indicates that the Rx L-Band Synthesizer is not locked. This alarm will
flash on during certain gateway parameter changes. A solid indication points toward a
configuration problem within the gateway.
o
Signal Lock
Indicates that the burst demodulator is unable to lock to a signal.
Minor
Alarms:
o
IFEC Lock
Reserved for future use.
o
Frame Lock
Indicates that the Framing Unit is unable to find the expected
framing
pattern.
o
EsNo Indicates Rx signal quality fallen below input threshold.
o
Carrier Level
Indicates Rx signal level has fallen below input threshold.
o
Test Pattern Sync
Reserved for future use
o
Carrier Level Cal
The gateway has not been properly calibrated.
Modulator Alarms: To view the detailed alarms of the modulator, select the Mod tab. The
Detailed Alarms screen for the modulator (Figure 7.4.6-2) will be displayed.