KPA Ku-Band Indoor Solid-State Power Amplifier

Revision 1

Appendix B

MN/KPA.IOM

B–9

B.4.1

Case Examples

Case 1. Backup

Å

Online unit(s)

1. Ensure the Online Unit attenuation is set to a value in dB greater than or equal (

≥ ) to the

difference in levels measured above.

2. With the Backup Unit forced to be the active unit, adjust the OFFSET value in the

CONFIG: Redundancy Æ SSPA#1 menu to approximately the difference measured
previously. This will be a negative (-) number.

3. Toggle between the Online and Backup units as being the active path by forcing and un-

forcing a backup through the Backup Unit’s CONFIG: Redundancy Æ SSPA#1 menu.
Ensure the output levels measured are equal. If necessary, re-adjust the Offset Value until
equal levels are measured. (Note that the Backup Unit’s total attenuation level as now
indicated in the CONFIG: Amp Æ Attenuation menu will be equal to the setting of the
Online Unit less the OFFSET value.)

For Example:

Online Unit Output Level

47.00 dBm

Backup Unit Output Level

45.25 dBm

Backup Unit Offset Value

0.00 dBm

Online Attenuation Setting

3.00 dB (must be >1.75 dB)

AFTER TOGGLING AND ADJUSTING:

Backup Offset Value

-1.75 dB

New Equalized Output Level

47.0 dBm

Backup Attenuation Setting

1.25 dB (3+(-1.75) = 1.25)

Section Notes: