3 config | redundancy page – Comtech EF Data KPA User Manual
Page 76

KPA Ku-Band Indoor Solid-State Power Amplifier
Revision 1
Ethernet Management
MN/KPA.IOM
6–14
6.5.4.3.3
Config | Redundancy page
IMPORTANT
Comtech EF Data’s KPA family of SSPAs are designed to automatically sense
and configure into Redundancy Mode when the redundant loop cable is
connected between the two (i.e., 1:1) or three (i.e., 1:2) KPAs comprising the
redundant subsystem.
The designation of each KPA in a redundant subsystem is determined
automatically via the redundancy interface cable connected – polling on the
dedicated redundancy bus will not begin until the redundancy loop cable is
connected.
Redundancy page in Automatic Mode
Redundancy page in Manual Mode
Redundancy page in Standalone Configuration (no redundant units recognized by system)
Figure 6-7. Config | Redundancy page
The ‘Config | Redundancy’ page (Figure 6-7) is used to control the operational parameters for
redundant operations. The active Redundancy Mode is identified on this page as 1:1, 1:2, or
OFF, and the appearance of the page itself varies depending on its Operating Mode.