KPA Ku-Band Indoor Solid-State Power Amplifier

Revision 1

Ethernet Management

MN/KPA.IOM

6–14

6.5.4.3.3

Config | Redundancy page

IMPORTANT

Comtech EF Data’s KPA family of SSPAs are designed to automatically sense
and configure into Redundancy Mode when the redundant loop cable is
connected between the two (i.e., 1:1) or three (i.e., 1:2) KPAs comprising the
redundant subsystem.

The designation of each KPA in a redundant subsystem is determined
automatically via the redundancy interface cable connected – polling on the
dedicated redundancy bus will not begin until the redundancy loop cable is
connected.










Redundancy page in Automatic Mode















Redundancy page in Manual Mode











Redundancy page in Standalone Configuration (no redundant units recognized by system)

Figure 6-7. Config | Redundancy page

The ‘Config | Redundancy’ page (Figure 6-7) is used to control the operational parameters for
redundant operations. The active Redundancy Mode is identified on this page as 1:1, 1:2, or
OFF, and the appearance of the page itself varies depending on its Operating Mode.