beautypg.com

3 kpa-080 specifications – Comtech EF Data KPA User Manual

Page 25

background image

Ku-Band Solid-State Power Amplifier

Revision 1

Introduction

MN/KPA.IOM

1–7

1.3.3 KPA-080 Specifications

Parameters

Specifications

Input

Impedance

50

Ω

Noise Figure

10 dB typical, 15 dB maximum @ max gain

VSWR 1.25:1

Maximum

Connector SMA

Female

Output

Frequency

14.0 to 14.5 GHz

Power

48.5 dBm min @ 1 dB Compression

Mute 60

dB

Impedance

50

Ω

VSWR 1.25:1

Maximum

Connector WR75G

Waveguide

Gain

Linear

61 dB minimum, 64 dB typical

Adjust

20 dB in 0.25 dB steps

Fill Band

± 0.75 dB

Per 40 MHz

± -0.25 dB

0 to +50

°C (32 to 122°F)

± 0.50 dB @ center frequency
± 1.00 dB full band

Third Order Modulation

Products

-30 dBc typical @ –25 dBc maximum @ 3 dB
total backoff (2 tones,

Δf = 1 MHz)

AM to PM Conversion

Output

2.0 degrees typical, 3.0 maximum @ rated output

Group Delay (per 40
MHz)

Linear

± 0.03 ns/MHz

Parabolic

± 0.003 ns/MHz

2

Ripple

1.0 ns Peak-to-Peak

Front Panel

Display

24 x 2 LCD

Data Entry

Cursor Control Keypad (6 keys)

Output Sample

Type N female, 50

Ω, –40 dBc

Input Sample

Type N female, 50

Ω, –20 dBc

Remote Control

COM Port

EIA-232 or EIA-485

Protocol

ASCII

Alarms

Summary Fault

Form C

LEDs

Power On

Green

Fault Red
Stored Fault

Red

TX On

Yellow

Online Yellow
Remote Yellow

Mechanical

Envelope

8.75H x 19W x 24D inches
(22.22H x 48.26W x 60.96D cm)

Weight

75 lbs (34 kg)

Environmental

Temperature Operating 0 to 50

°C (32 to 122°F)

Storage

–40 to 70

°C (–40 to 158°F)

Humidity Operating

10 to 95% Noncondensing

Storage

0 to 100% Noncondensing

Altitude Operating

15, 000 ft MSL

Storage

50, 000 ft

Shock

Normal Commercial Shipping and Handling

Power Requirements

VAC

180 to 270 VAC, 47 to 63 Hz
1100W nominal