Management Information Base

,

Rev. 1

Appendix A,

MIB Listing

A-83

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This is the IF Center frequency of the transponder,

depending on the specific

hardware involved, 70 or 140 MHz."

::= { transponderTableEntry 6 }


-- ranges from 2.0 GHz ro 15.0 GHz
(unit in Hz)

transponderLBandUplinkFactor OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"Enter the value (in GigaHertz) for the Uplink Factor

to be used for low- or high-side injection

calculations.

Difference between RF up link center

and the L band center frequency."

::= { transponderTableEntry 7 }


-- unit in Hz

transponderLBandDownlinkFactor OBJECT-TYPE
SYNTAX

REAL

ACCESS read-only
STATUS mandatory
DESCRIPTION

"Enter the value (in GigaHertz) for the Downlink

Factor to be used for low- or high-side injection

calculations.

Downlink Factor = Uplink Factor Translation Factor

This is difference between RF down link

center and L band center frequency."

::= { transponderTableEntry 8 }


-- unit in Hz

transponderLBandCenter OBJECT-TYPE
SYNTAX

LONGINT

ACCESS read-only
STATUS mandatory

::= { transponderTableEntry 9 }


transponderHighSideInjection OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-write
STATUS mandatory
DESCRIPTION

"High-side injection is calculated as follows:

LBand = Uplink Factor RF Uplink

- or -

L-band = Downlink Factor RF Downlink

Indicate whether the LO frequency is higher

than (high side injection) or lower than