Comtech EF Data MIDAS Management Information Base User Manual
Page 142

Management Information Base
,
Rev. 1
A-126 Appendix A,
MIB Listing
SYNTAX
TMODULATION
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MODULATION
This allows the operator to select the
modulation standard to be used for the
connection. Choices include: BPSK, QPSK,
8PSK,
16QAM,
etc."
::= { activeCallTableEntry 1101 }
activecallLinkParamsAFECRate OBJECT-TYPE
SYNTAX
TFECRATE
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FEC
RATE
To select the forward error correction
rate (FEC) to be used for the channel.
Choices include:1/2, 2/3, 3/4, 5/6, 7/8,
etc."
::= { activeCallTableEntry 1102 }
activecallLinkParamsADataRate OBJECT-TYPE
SYNTAX
LONGINT
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the data rate from the list of
available choices, or enter any data
rate that is valid for the traffic
modem."
::= { activeCallTableEntry 1103 }
activecallLinkParamsAPowerLevel OBJECT-TYPE
SYNTAX
REAL
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field allows the operator to enter
the TX power level setting of the traffic
modem. Power range limits (0 to -30 dBm)"
::= { activeCallTableEntry 1104 }
activecallLinkParamsAClockMode OBJECT-TYPE
SYNTAX
TCLOCKMODE
ACCESS read-only
STATUS mandatory
DESCRIPTION
"To select the clock mode. Choices include:
Terrestrial, Internal, Satellite, and
External
Reference."
::= { activeCallTableEntry 1105 }
activecallLinkParamsAPreset OBJECT-TYPE
SYNTAX
TPRESET
ACCESS read-only