channelAUPCParamsMaxPowerDelta OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"+3.0 .. +20.0 dB default: +10 dB
If AUPC is used in the circuit, this
is the maximum increase in the power
from nominal during the call"
::= { channelTableEntry 101 }
channelAUPCParamsMinPowerDelta OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"-3.0 .. -20 dB default: -10 dB
If AUPC is used, the maximum decrease
from
nominal
power"
::= { channelTableEntry 102 }
channelAUPCParamsTargetEbNo OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"+3.2 .. +16.0 dB default: 12 dB"
::= { channelTableEntry 103 }
channelAUPCParamsTrackingRate OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0.5 .. 6.0 dB/min default: 2.0 db/min
Maximum rate of change of power
during an AUPC call."
::= { channelTableEntry 104 }
channelAUPCParamsLocalAction OBJECT-TYPE
SYNTAX
TCARRIERLOSSACTION
ACCESS read-write
STATUS mandatory
DESCRIPTION
"default:max
Action to take at channel A if channel A
loses
carrier
lock."
::= { channelTableEntry 105 }
channelAUPCParamsRemoteAction OBJECT-TYPE
SYNTAX
TCARRIERLOSSACTION
ACCESS read-write
STATUS mandatory
DESCRIPTION
"default:
max