A-111

modem."

::= { multiPointCircuitTableEntry 203 }


multipointcircuitBPowerLevel OBJECT-TYPE
SYNTAX

REAL

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This field allows the operator to enter

the TX power level setting of the traffic

modem. Power range limits (0 to -30 dBm) "

::= { multiPointCircuitTableEntry 204 }


multipointcircuitBClockMode OBJECT-TYPE
SYNTAX

TCLOCKMODE

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This allows the operator to select the clock

mode. Choices include: Terrestrial, Internal,

Satellite, and External Reference."

::= { multiPointCircuitTableEntry 205 }


multipointcircuitBPreset OBJECT-TYPE
SYNTAX

TPRESET

ACCESS read-write
STATUS mandatory
DESCRIPTION

"This allows the operator to select the

preset option for the traffic modem.

Choices depend on the modem type, but

generally include: No, A, B, C, D. For

modems with no presets, this is always

set to No. Choosing a preset overrides

the Modulation, FEC Rate, and Data Rate

settings."

::= { multiPointCircuitTableEntry 206 }


multipointcircuitBReedSolomon OBJECT-TYPE
SYNTAX

BOOLEAN

ACCESS read-write
STATUS obsolete
DESCRIPTION

"To select Enable/Disable Reed-Solomon."

::= { multiPointCircuitTableEntry 207 }


multipointcircuitBEncode OBJECT-TYPE
SYNTAX

TENCODE

ACCESS read-write
STATUS mandatory
DESCRIPTION

"To select the encoding type. Choices

include: Viterbi, Sequential, etc."

::= { multiPointCircuitTableEntry 208 }


multipointcircuitBVoiceProtocol OBJECT-TYPE
SYNTAX

TVPROTOCOL