A-21
"To select the clock mode. Choices include:
Terrestrial, Internal, Satellite, and
External
Reference."
::= { sysVideoASetup 7 }
videoAsetupRingTimeOut OBJECT-TYPE
SYNTAX
WORD
ACCESS read-write
STATUS mandatory
::= { sysVideoASetup 8 }
videoAsetupCallTimeout OBJECT-TYPE
SYNTAX
THALFLONGWORD
ACCESS read-write
STATUS mandatory
::= { sysVideoASetup 9 }
videoAsetupGradeofService OBJECT-TYPE
SYNTAX
TVIDEOGRADEOFSERVICE
ACCESS read-write
STATUS mandatory
::= { sysVideoASetup 10 }
videoAsetupInterfaceBuffer OBJECT-TYPE
SYNTAX
THALFLONGWORD
ACCESS read-write
STATUS mandatory
::= { sysVideoASetup 11 }
sysVideoBSetup OBJECT IDENTIFIER ::= { systemSetup 7 }
videoBsetupPowerLevel OBJECT-TYPE
SYNTAX
REAL
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Returning channel video default values"
::= { sysVideoBSetup 1 }
videoBsetupModulation OBJECT-TYPE
SYNTAX
TMODULATION
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This allows the operator to select the
modulation standard to be used for the
connection. Choices include: BPSK, QPSK,
8PSK,
16QAM,
etc."
::= { sysVideoBSetup 2 }
videoBsetupDataRate OBJECT-TYPE
SYNTAX
THALFLONGWORD
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the data rate from the list of
available choices, or enter any data